Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
913
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00506
C00507
Parameter | Name:
C00506 | PW protection internal config
Data type: UNSIGNED_16
Index: 24069
d
= 5E05
h
From version 15.00.00
Configuration of the password protection for device-internal parameter access
Individual password protection for single communication channels
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Only access to user menu
The menus in the keypad are reduced. Only the user
menu can be used to change parameters.
Bit 1 Parameter write protection
Via system blocks (
), write/read parameters cannot be
written.
Bit 2 Parameter read protection
Via system blocks (
), write/read parameters cannot be
read.
Bit 3
Reserved
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Subcodes
Lenze setting
Info
C00506/1
0x0007
PW protection internal config
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C00507 | Current password protection
Data type: UNSIGNED_16
Index: 24068
d
= 5E04
h
From version 06.00.00
Display of the currently active device access protection (password protection and device personalisation)
Note:
As the password protection can be configured individually for each single communication channel
from version
15.00.00
bit 1 and bit 2 indicate the active protection always with regard to the communication channel used.
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Only access to user menu
1
≡
The menus in the keypad are reduced. Only the user
menu can be used to change parameters.