3
Commissioning
3.8
Commissioning of the "Table positioning" technology application
74
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
The
Encoder/Feedback system
parameterisation dialog will be shown:
3. In the
Position encoder selection
list field (
), select "Encoder signal FreqIn12".
4. Set the number of position encoder increments in the
Number of encoder increments at
FreqIn12
input field (
).
5. In the
Fct. DI 1/2 100kHz
list field (
), select "DI1(6)&DI2(7)=FreqIn (2-track)".
This selection ensures that the digital DI1 and DI2 input terminals are configured as frequency
inputs.
6. Adapt the proportional gain,
Kp position controller
), if necessary. This parameter can
be found on the second page of the dialog and can be reached via the
>>>
button.
7. Click the
Close
button to close the parameterisation dialog again.
Related topics:
Using DI1(6) and DI2(7) as frequency inputs