17
Function library
17.2
System blocks | LS_ParReadWrite_1-6
1553
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Error status
• If
bFail
= TRUE:
Error status is displayed.
• Subcode 1 =
LS_ParReadWrite_1
Subcode 2 =
LS_ParReadWrite_2
...
Subcode 6 =
LS_ParReadWrite_6
0 No error
33803 Invalid data type (e.g. STRING)
33804 Limit violation
33806 Invalid code
33813 No element of the selection list
33815 Writing of the parameter not
permitted
33816 Writing of the parameter only
permitted if controller is inhibited
33829 Invalid subcode
33865 No parameter with subcodes
(from version 06.00.00)
Arithmetic mode
• Lenze setting:"0: No arithmetic"
0 No arithmetic
1 In16Bit: LW=+/-32767
2 In16Bit: HW=+/-; LW=0..65535
3 In32Bit: HW_LW=+/-2147483647
(from version 06.00.00)
-32767
32767 Counter
• For internal conversion in
arithmetic modes 1 ... 3.
• Lenze setting: 1
(from version 06.00.00)
1
32767 Denominator
• For internal conversion in
arithmetic modes 1 ... 3.
• Lenze setting: 1
Parameters
Possible settings
Info