7
Technology applications
7.5
TA "Switch-off positioning"
470
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Switch-off positioning
bJogCtrlInputSel1
bJogCtrlInputSel2
BOOL
Selection inputs for a binary coded selection of the switch-off position 1 ... 3
• Activation of the signal pairs
bJogCtrlSlowDown1/bJogCtrlStop1
,
bJogCtrlSlowDown2/bJogCtrlStop2
or
bJogCtrlSlowDown3/bJogCtrlStop3
according to the
Truth table for activating the pre-switch off
bJogCtrlRfgIn
BOOL
Ramping down of the setpoint generator in the downstream
FB according to
the
Truth table for activating the pre-switch off
bJogCtrlJog1
bJogCtrlJog2
BOOL
Inputs for overriding fixed setpoints (JOG setpoints) for the main setpoint
• If the pre-switch off is inactive (
bJogCtrlInputSel1
and
bJogCtrlInputSel2
are both
set to FALSE), the two control signals are passed through 1:1 to the downstream
FB
• To achieve the desired behaviour (starting at high speed, pre-switch off at low
speed), both inputs must be set to TRUE.
• Fixed setpoint 2 must be less than fixed setpoint 3!
Otherwise, the drive will start at a low speed and accelerate after the pre-switch
off.
• If in additional to the inputs
bJogCtrlJog1
and
bJogCtrlJog2
the selection inputs
bJogSpeed4
and
bJogSpeed8
are assigned, different fixed setpoints can result
from this and the drive may travel with different speeds than selected via
bJogCtrlJog1
and
bJogCtrlJog2
.
bJogCtrlSlowDown1
bJogCtrlSlowDown2
bJogCtrlSlowDown3
BOOL
Activation of fixed setpoint 2 in the downstream
• These inputs only have a function if they have been previously activated via
bJogCtrlInputSel1
and
bJogCtrlInputSel2
(see
Truth table for activating the pre-
bJogCtrlStop1
bJogCtrlStop2
bJogCtrlStop3
BOOL
Ramping down of the ramp function generator in the downstream
FB
• These inputs only have a function if they have been previously activated via
bJogCtrlInputSel1
and
bJogCtrlInputSel2
(see
Truth table for activating the pre-
bJogSpeed4
bJogSpeed8
BOOL
Inputs for overriding fixed setpoints (JOG setpoints) for the main setpoint
• A fixed setpoint for the setpoint generator can be activated instead of the main
setpoint via these selection inputs.
• The selection inputs are binary coded.
• For a detailed functional description see the
FB.
bJogRamp1 ... bJogRamp8
BOOL
Selection inputs for alternative acceleration/deceleration times for the main
setpoint
• The four selection inputs are binary coded, therefore 15 alternative
acceleration/deceleration times can be selected.
• For main setpoint
nMainSetValue_a
, the set acceleration time (
deceleration time (
) are active in the case of the binary coded selection "0"
(all inputs = FALSE or not assigned).
• Alternative acceleration times are selected in
.
• The selection of the alternative deceleration times is carried out in
.
• For a detailed functional description see the
FB.
MCK basic functions
bMBrakeRelease
BOOL
: Release/apply brake
• In conjunction with the operating mode selected in
(Lenze setting: "Brake control off").
FALSE Apply brake.
• During automatic operation, the internal brake logic controls the
brake.
TRUE Release brake manually (forced release).
•
Note!
The brake can also be released when the controller is inhibited!
• During automatic operation, the internal brake logic is
deactivated and the brake is released (supervisor operation). If a
controller inhibit has been set by the brake control, it will be
deactivated.
• In semi-automatic operation, the brake is released including
feedforward control.
Designator
Data type
Information/possible settings