15
Parameter reference
15.2
Parameter list
1098
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01671
C01672
C01700
Parameter | Name:
C01671 | L_ComparePhi 1-5: Hysteresis
Data type: INTEGER_32
Index: 22904
d
= 5978
h
Hysteresis for the comparison function
Setting range
(min. value | unit | max. value)
0
Incr.
1073741824
Subcodes
Lenze setting
Info
C01671/1
0 incr.
C01671/2
0 incr.
C01671/3
0 incr.
C01671/4
0 incr.
C01671/5
0 incr.
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01672 | L_ComparePhi 1-5: Window
Data type: INTEGER_32
Index: 22903
d
= 5977
h
Window for the comparison operation
Setting range
(min. value | unit | max. value)
0
Incr.
1073741824
Subcodes
Lenze setting
Info
C01672/1
0 incr.
: Window
C01672/2
0 incr.
: Window
C01672/3
0 incr.
: Window
C01672/4
0 incr.
: Window
C01672/5
0 incr.
: Window
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01700 | Energy saving mode: Mode
Data type: UNSIGNED_8
Index: 22875
d
= 595B
h
From version 17.00.00 onwards
Display of the energy saving modes maximally provided
Display range
(min. value | unit | max. value)
0
1
Subcodes
Info
C01700/1
Number of energy saving modes maximally provided = 1
C01700/2
Current mode
• 1
≡
Energy saving mode is active
• 0
≡
Energy saving mode is not active
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1