Function library
17.2
System blocks | LS_ParFreeUnit_2
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.2.27
LS_ParFreeUnit_2
This system block outputs 16 parameterisable position signals.
• In contrast to the SB
, the positions are set in the application unit [unit] instead of
in [increments].
• The
bDataValid
status signal indicates that the internal position conversion is completed and
the output data are consistent.
Outputs
Parameters
Designator
Data type
Value/meaning
bDataValid
BOOL
Status signal "Position conversion completed, data consistent"
TRUE The conversion of the positions from [unit] to [increments] is
completed.
dnC475_17 ... dnC475_32
DINT
Output of the position signals parameterised in
in [increments]
• Observe
bDataValid
status signal!
Parameters
Possible settings
Info
-214748.3647
Unit
214748.3647 Setting of the position signals to be
output