15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02866
Bit 6 Motorident.: Calculation C11 C22
C497 C966 C982
From version 12.00.00 onwards
: Following successful
motor parameter identification, further controller
parameters can be calculated automatically.
If these parameters are to be calculated, bit 6 must be set
to "1".
0
≡
Do not calculate parameter
1
≡
Calculate parameter
Automatic motor data identification
Bit 7 Brake chopper off in case of pulse
inhibit
From version 14.00.00
0
≡
No response of the brake chopper in case of pulse
inhibit.
1
≡
In case of pulse inhibit, the brake chopper is
permanently switched off without any delay.
Braking operation/brake energy management
Bit 8 DC-bus supply with DC charging
connection
Bit 9 Inverter characteristics inactive
From version 12.00.00
In case of very low-inductance motors (e.g. synchronous
motor with a rated frequency of 1000 Hz) the inverter
error characteristic needs to be switched off as otherwise
the current of the device might be switched off.
0
≡
Inverter error characteristic is active
1
≡
Inverter error characteristic is not active
Bit 10 SCPSM: Extrapolation - actual speed
value inactive
Bit 11 TopLine: Speed encoder signal cycle
500us
Bit 12 In case of QSP - nTorqueSetValue_a
active
From version 13.00.00
Bit 13 In case of QSP - nTorquexxxLimit_a
active
From version 13.00.00
Bit 14 Sensitivity of setpoint feedf. ctrl. 16
bits
From version 14.00.00
Bit 15 SC: Dead time of speed setpoint
500us
From version 14.00.00
Subcodes
Lenze setting
Info
C02865/1
0x0000
: Special settings
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C02865 | MCTRL: Special settings
Data type: UNSIGNED_16
Index: 21710
d
= 54CE
h
Parameter | Name:
C02866 | MCTRL: Special settings
Data type: UNSIGNED_8
Index: 21709
d
= 54CD
h
Activation of special functions of the internal motor control
Selection list
0 No
1 Yes