Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
975
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00822
C00823
C00821/3
0: FALSE
: bOut: bIn3...bIn1=0 1 0
C00821/4
0: FALSE
: bOut: bIn3...bIn1=0 1 1
C00821/5
0: FALSE
: bOut: bIn3...bIn1=1 0 0
C00821/6
0: FALSE
: bOut: bIn3...bIn1=1 0 1
C00821/7
0: FALSE
: bOut: bIn3...bIn1=1 1 0
C00821/8
0: FALSE
: bOut: bIn3...bIn1=1 1 1
C00821/9
0: FALSE
: bOut2: bIn3...bIn1=0 0 0
C00821/10
0: FALSE
: bOut2: bIn3...bIn1=0 0 1
C00821/11
0: FALSE
: bOut2: bIn3...bIn1=0 1 0
C00821/12
0: FALSE
: bOut2: bIn3...bIn1=0 1 1
C00821/13
0: FALSE
: bOut2: bIn3...bIn1=1 0 0
C00821/14
0: FALSE
: bOut2: bIn3...bIn1=1 0 1
C00821/15
0: FALSE
: bOut2: bIn3...bIn1=1 1 0
C00821/16
0: FALSE
: bOut2: bIn3...bIn1=1 1 1
C00821/17
0: FALSE
: bOut3: bIn3...bIn1=0 0 0
C00821/18
0: FALSE
: bOut3: bIn3...bIn1=0 0 1
C00821/19
0: FALSE
: bOut3: bIn3...bIn1=0 1 0
C00821/20
0: FALSE
: bOut3: bIn3...bIn1=0 1 1
C00821/21
0: FALSE
: bOut3: bIn3...bIn1=1 0 0
C00821/22
0: FALSE
: bOut3: bIn3...bIn1=1 0 1
C00821/23
0: FALSE
: bOut3: bIn3...bIn1=1 1 0
C00821/24
0: FALSE
: bOut3: bIn3...bIn1=1 1 1
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00821 | L_DigitalLogic_1: Truth table
Data type: UNSIGNED_8
Index: 23754
d
= 5CCA
h
Parameter | Name:
C00822 | L_DigitalLogic_2: Function
Data type: UNSIGNED_8
Index: 23753
d
= 5CC9
h
The
FB: Selection of the internal logic function
Selection list
(Lenze setting printed in bold)
Info
0 bOut = 0
Constant value "FALSE"
1 bOut = 1
Constant value "TRUE"
2 bOut = bIn1 AND ... bIn3
AND operation
3 bOut = bIn1 OR ... bIn3
OR operation
4 bOut = f (truth table)
The truth table parameterised in
is used.
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00823 | L_DigitalLogic_2: Truth table
Data type: UNSIGNED_8
Index: 23752
d
= 5CC8
h
The
FB: Parameterisation of the truth table
Selection list
0 False
1 True
Subcodes
Lenze setting
Info