Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
1137
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02607
C02610
Parameter | Name:
C02607 | Holding brake: Status
Data type: UNSIGNED_16
Index: 21968
d
= 55D0
h
Switching status of the holding brake control
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Brake applied
1
≡
Holding brake is completely applied
Bit 1 Brake released
1
≡
Holding brake is completely released
Bit 2 Feedforward control active
1
≡
Feedforward control for holding of the load via the
motor is active before the holding brake releases.
Bit 3 Closing active
1
≡
The brake closing time (
) expires
Bit 4 Forced release active
1
≡
In case of automatic operation of the holding brake
control, the brake is directly released via the MCK input
bMBrakeRelease
= TRUE
Bit 5 Release active
1
≡
The brake release time (
) expires
Bit 6 Setpoint synchronisation active
1
≡
A speed setpoint at the MCK is approached along a
defined ramp after brake release
Bit 7 Signalling contact error
1
≡
The status monitoring has tripped
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C02610 | MCK: Accel./decel. times
Data type: UNSIGNED_32
Index: 21965
d
= 55CD
h
Ramp times for speed setpoint synchronisation
Setting range
(min. value | unit | max. value)
0.000
s
999.999