Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
1085
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01248
Bit 10 Max. speed limit
1
≡
Due to the set machine parameters, the maximum
speed for specifications in [units/s] are limited to the
factor 150 %.
Bit 11 Quick stop is active
1
≡
Quick stop function is active.
Bit 12 Quick stop standstill is active
1
≡
Standstill during active quick stop function (no ramp
generation).
Bit 13 Max. speed is pending
1
≡
The speed setpoint has exceeded the limit of
±
199.99 %.
Possible cause:
• Too high influence due to speed override
• Increased speed by reduced acceleration with little
jerk
Bit 14 Position resolution limit
1
≡
The position resolution calculated by machine data
entries has been limited to the maximum display area of
214748.3647 [Incr./Unit] with reference to the display in
. The real value is higher!
Bit 15 Modulo buffer overflow
Bit 16 Ck10: position > cycle length
Bit 17 Ck10: invalid speed
Bit 18 Ck10: invalid acceleration
Bit 19 Ck10: invalid deceleration
Bit 20 Ck10: invalid final speed
Bit 21 Ck10: reversal at overchange
Bit 22 Ck10: distance calculation error
Bit 23
Reserved
Bit 24
Reserved
Bit 25
Reserved
Bit 26
Reserved
Bit 27
Reserved
Bit 28
Reserved
Bit 29
Reserved
Bit 30
Reserved
Bit 31
Reserved
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C01247 | MCK: Diagnostic word
Data type: UNSIGNED_32
Index: 23328
d
= 5B20
h
Parameter | Name:
C01248 | MCK: Ref. step
Data type: UNSIGNED_8
Index: 23327
d
= 5B1F
h
From version 16.00.00
Selection list
Info
0 No Operation
Initial step when changing to the homing mode
1 RefMarke: Search
Search travel until reference pre-stop mark
2 RefMarke: Stop
Stop when reference pre-stop mark has been detected
3 RefMarke: Reversal
Reversal of reference pre-stop mark
4 HW-Limit: Search
Search travel until limit switch
5 HW-Limit: Stop
Stop when limit switch has been detected
6 HW-Limit: Reversal
Reversal of limit switch
7 M-Limit: Search
Search travel until torque limit has been detected