4.2.10
Fault
This device status will be active as soon as a monitoring mode responds the error response "Fault"
has been parameterised for.
• The motor has no torque (is coasting) when the inverter is inhibited.
• The error must explicitly be reset ("acknowledged") in order to exit the device status, e.g. by the
device command "
" or via the control bit "ResetFault" in the control word
wCanControl
or
wMCIControl
.
Related topics:
wCANControl/wMCIControl control words
Basics on error handling in the inverter
Error messages of the operating system
4.2.11
SystemFault
This device state is not used since the inverter lacks the activating event.
This device status becomes active if a system fault occurs.
• The device status can only be abandoned by
• mains switching or
• a system restart.
"DRV-RDY" LED
LED "DRV-ERR"
Display in
Display in status word 1 (
)
Bit 11
Bit 10
Bit 9
Bit 8
OFF
Fault
1
0
0
0
Note!
If an undervoltage in the DC bus of the inverter occurs (error message "LU"), the device
changes to the "
An additional error of higher priority leads the device into the "
" status.
, the device changes to the "
"
status after acknowledging the error although the undervoltage is still available!
If the "Inhibit at fault" auto-start option has been activated in
,
explicit
deactivation of the controller inhibit is required before the status can be abandoned.
"DRV-RDY" LED
LED "DRV-ERR"
Display in
Display in status word 1 (
)
Bit 11
Bit 10
Bit 9
Bit 8
OFF
SystemFault
1
0
1
1