4
Device control (DCTRL)
4.4
Internal interfaces | "LS_DriveInterface" system block
130
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Tip!
If a bus control is not wanted (e.g. in case of control via terminals):
Connect both control word inputs with the
wDriveCtrl
output signal of the
system block. This output signal has the fixed value "9", which corresponds to the following
assignment:
• Bit 0, SwitchOn = 1
• Bit 3, EnableOperation = 1
• All others: 0
Note!
The assignment of bits 11 ... 13 and bit 15 depends on the technology application
selected in
• See description of the corresponding technology application.
Bit
Name
Function
Bit 0 SwitchOn
1
≡
Change to the "
" device status
•
From version 05.01.00 onwards, the following applies:
This bit must be set in
the CAN
AND
MCI control word in order that the drive changes to the
"
" device state after mains connection. In order to reach the
"
" state, it is sufficient to set the bit to 0 in one of the two
control words.
•
Up to and including version 05.00.00 the following applies:
This bit must be
set in the CAN
OR
MCI control word in order that the drive changes to the
"
" state after mains connection.
Bit 1 DisableVoltage
1
≡
Inhibit inverter control (pulse inhibit)
Bit 2 SetQuickStop
Activate quick stop (QSP)
Activate/deactivate quick stop (
Bit 3 EnableOperation
1
≡
Enable inverter (RFR)
• This bit must be set in CAN
AND
in the MCI control word, otherwise the
controller will be inhibited.
Bit 4 ModeSpecific_1
Reserved (currently not assigned)
Bit 5 ModeSpecific_2
Bit 6 ModeSpecific_3
Bit 7 ResetFault
1
≡
Reset fault (trip reset)
• Acknowledge error message (if the error cause has been eliminated).
Bit 8 SetHalt
1
≡
Activate stop function
• Stop drive via stopping ramp (in preparation).
Bit 9 reserved_1
Reserved (currently not assigned)
Bit 10 reserved_2
Bit 11 LenzeSpecific_1
Assignment depends on the selected technology application
• See description of the corresponding technology application.
Bit 12 LenzeSpecific_2
Bit 13 LenzeSpecific_3
Bit 14 SetFail
1
≡
Set error (trip set)
Bit 15 LenzeSpecific_4
Assignment depends on the selected technology application
• See description of the corresponding technology application.