
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
835
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00103
C00104
Parameter | Name:
C00103 | Add. decel. time x
Data type: UNSIGNED_32
Index: 24472
d
= 5F98
h
The
FB: Additional deceleration times for the main setpoint
• The additional deceleration times set here can be selected via the binary inputs
bTI1
...
bTI8
of the
FB.
Setting range
(min. value | unit | max. value)
0.000
s
999.999
Subcodes
Lenze setting
Info
C00103/1
0.000 s
Add. decel. time 1 ... 15
C00103/...
C00103/15
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1000
Parameter | Name:
C00104 | Quick stop setting
Data type: UNSIGNED_16
Index: 24471
d
= 5F97
h
From version 10.00.00
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Standstill position-controlled
1
≡
At standstill the position control is activated.
The basic conditions are shown in the
for
the quick stop function.
Bit 1 Ramp position-controlled
1
≡
During the ramp-down phase, the position control is
activated.
The basic conditions are shown in the
for
the quick stop function.
Bit 2 Continue following error
From version 15.00.00
1
≡
The current following error is continued if the quick
stop with position control is activated while ramping
down.
Bit 3 Starting value is the setpoint speed
From version 15.00.00
0
≡
The starting value at quick stop is the actual speed if
it derives more than 5 rpm from the setpoint. This serves
to prevent a jump to a strongly differing setpoint.
1
≡
The starting value for quick stop is the setpoint
speed .
Bit 4 Use position encoder
From version 15.00.00
1
≡
In case of quick stop with position control, the
position encoder is used instead of the speed encoder.
The basic conditions are shown in the
for
the quick stop function.
Bit 5 Standstill depending on the actual
speed
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved