Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
781
12
Fieldbus interface (MCI)
12.1
Process data transfer
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.1
Process data transfer
The process data serve to control the inverter. Thus the transfer of the process data is time-critical.
• The process cycle is 1 ms, irrespective of the respectively plugged-in bus system and the type of
inverter.
• The process data transfer between the host system and the inverters is cyclical.
• This concerns the continuous exchange of current input and output data.
• In the case of the 8400 inverter, 16 words per direction are exchanged.
• The master computer can directly access the process data.
Access to the process data takes place via the port blocks
LP_MciIn
and
LP_MciOut
(see FB
interconnection of the »Engineer«).
These port blocks are also called process data channels.
• The process data are not saved in the inverter.
[12-1] External and internal data transfer between bus system, inverter and function block interconnection