Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
1073
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01222
C01223
C01224
13 <_Ln
Negative direction - to neg. limit switch
14 >_Mlim
Positive direction towards torque limit (
15 <_Mlim
Negative direction towards torque limit (
)
100 SetRef
Direct acceptance and setting of the home position
• The measuring system is set based on the home
position parameterised in
at standstill.
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01221 | MCK: Ref. mode
Data type: UNSIGNED_8
Index: 23354
d
= 5B3A
h
Parameter | Name:
C01222 | MCK: Ref. M limit mode 14/15
Data type: INTEGER_16
Index: 23353
d
= 5B39
h
Torque limit for homing modes 14 and 15 (homing towards positive stop)
• 100 %
≡
maximum torque (
)
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
199.99
10.00 %
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C01223 | MCK: Ref. waiting time mode 14/15
Data type: UNSIGNED_16
Index: 23352
d
= 5B38
h
Blocking time for homing modes 14 and 15 (homing towards positive stop)
• The reference is set if an excess of the torque limit set in
has been deteced over a time period defined
here.
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
65000
100 ms
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01224 | MCK: Ref. speeds
Data type: INTEGER_32
Index: 23351
d
= 5B37
h
Speeds for reference search/homing
Setting range
(min. value | unit | max. value)
0.0000
unit/s
214748.3647
Subcodes
Lenze setting
Info
C01224/1
720.0000 unit/s
MCK: Ref. initial speed
• Start speed for quick approach of the limit switch/
pre-stop mark (depending on the selected homing
mode).
C01224/2
180.0000 unit/s
MCK: Ref. search speed
• Search speed for slower - but more precise -
approaching of the touch probe sensor (sensor
reference signal).
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10000