Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
1121
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02278
C02279
C02280
C02276/1
6.00 mm^2
: c916_val1
C02276/2
6.00 mm^2
: c916_val2
C02276/3
6.00 mm^2
: c916_val3
C02276/4
6.00 mm^2
: c916_val4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C02276 | LS_WriteParamList: Motor cable cross-section
Data type: UNSIGNED_16
Index: 22299
d
= 571B
h
Parameter | Name:
C02278 | LS_WriteParamList: PSM: Maximum motor current field weakening
Data type: UNSIGNED_16
Index: 22297
d
= 5719
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.00
%
500.00
Subcodes
Lenze setting
Info
C02278/1
30.00 %
: c938_val1
C02278/2
30.00 %
: c938_val2
C02278/3
30.00 %
: c938_val3
C02278/4
30.00 %
: c938_val4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C02279 | LS_WriteParamList: Ultimate motor current
Data type: UNSIGNED_16
Index: 22296
d
= 5718
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.0
A
3000.0
Subcodes
Lenze setting
Info
C02279/1
3000.0 A
: c939_val1
C02279/2
3000.0 A
: c939_val2
C02279/3
3000.0 A
: c939_val3
C02279/4
3000.0 A
: c939_val4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10
Parameter | Name:
C02280 | LS_WriteParamList: Max. motor speed
Data type: UNSIGNED_16
Index: 22295
d
= 5717
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
50
rpm
65000
Subcodes
Lenze setting
Info
C02280/1
60000 rpm
: c965_val1
C02280/2
60000 rpm
: c965_val2
C02280/3
60000 rpm
: c965_val3
C02280/4
60000 rpm
: c965_val4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1