17
Function library
17.1
Function blocks | L_ConvPP_1
1303
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.45
L_ConvPP_1
This FB converts a position with dynamic fraction.
Inputs
Outputs
Designator
Data type
Information/possible settings
dnIn_p
DINT
Input signal
bAct_b
BOOL
Conversion mode
FALSE
TRUE
nNum
INT
Factor (numerator)
• Internal limitation to -32767 ... -1 / 1 ... 32767
wDenom
WORD
Factor (denominator)
• Internal limitation to 1 ... 32767
Designator
Data type
Value/meaning
dnOut_p
DINT
Output signal
• Internal limitation to ±2
31
-1 (±2147483647)
Note!
Conversion is remainder considered.
/B&RQY33B
GQ,QBS
GQ2XWBS
Q1XP
E$FWBE
Z'HQRP
Q1XP
Z'HQRP
dnOut_p
Remainder
nNum
wDenom
-----------------------
⋅
=
dnOut_p
dnIn_p
nNum
wDenom
-----------------------
⋅
=