15
Parameter reference
15.2
Parameter list
886
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00371
C00372
C00381
C00385
Parameter | Name:
C00371 | CAN ErrorCode
Data type: UNSIGNED_16
Index: 24204
d
= 5E8C
h
From version 13.00.00
Display range
(min. value | unit | max. value)
0
65535
Subcodes
Info
C00371/1
CAN ErrorCode
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00372 | CAN_Tx_Rx_Error
Data type: UNSIGNED_8
Index: 24203
d
= 5E8B
h
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C00372/1
CAN Tx_Error
C00372/2
CAN Rx_Error
C00372/3
CAN Tx_Overflow
C00372/4
CAN Rx_Overflow
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00381 | CAN Heartbeat producer time
Data type: UNSIGNED_16
Index: 24194
d
= 5E82
h
Time interval for the transmission of the heartbeat telegram to the consumer(s).
• The heartbeat telegram is sent automatically as soon as a time > 0 ms is set.
• Mapping of the CANopen object
(see DS301 V4.02).
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
65535
0 ms
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00385 | CAN node addr. HeartBeat producer
Data type: UNSIGNED_8
Index: 24190
d
= 5E7E
h
The subcodes represent the nodes to be monitored by heartbeat.
Setting range
(min. value | unit | max. value)
0
127
Subcodes
Lenze setting
Info
C00385/1
0
CAN node address HeartBeat producer 1 ... 15
C00385/...
C00385/15
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1