Test Results
NetBlazer
385
Service Configuration - Ramp
Service Configuration - Ramp
From the
Test
menu, tap
Results
,
Service Configuration
, and the
Ramp
tab.
Service Name and Selection
Service Name
indicates the name of the selected service. Select the
service to be displayed by either using the left/right arrow or by tapping
over the service numbers area then tapping on a specific service number.
An orange background indicates the selected service while a green
background indicates the services that are enabled.
Committed/Excess Steps
Committed Steps
indicate the pre CIR and CIR steps specified in the
ramp configuration.
Excess Steps
indicate the
CIR+EIR
and
Traffic Policing
steps
specified in the ramp configuration.
Direction
, available with
Dual Test Set
, indicates results from local to
remote (
L->R
) and remote to local (
R->L
).
TX Rate
indicates the transmission rate for each step.
SLA Verified
indicates the committed SLA parameters that are used to
declare the pass/fail verdict. See
on page 405 for
more information on
Frame Loss
,
Max Jitter
,
Round-Trip Latency
,
and
Max RX Rate
.
Informational
parameters are for information purpose only, they are
not included in the test pass/fail verdict. See
page 405 for more information on
Frame Loss
,
Max Jitter
, and
Round-Trip Latency
.
Average RX Rate
indicates the measured average utilization
throughput for each step.
Summary of Contents for FTB-1
Page 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Page 12: ......
Page 20: ......
Page 22: ......
Page 52: ......
Page 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Page 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Page 84: ......
Page 98: ......
Page 298: ......
Page 574: ......
Page 652: ......
Page 674: ...0 5 1 5 48 5 0 176 W d y K y K D...