Test Functions
506
FTB-700G/800 Series
Pointer Adjustment
Pointer Adjustment
From the
Test
menu, tap
Functions
, and the
Pointer Adjustment
tab.
TX Pointer Adjustment
Note:
Only available in
Coupled
topology.
The pointer adjustment supports two modes of operation:
Manual
and
Sequence
. Both modes offer the generation of pointer events even when
the test is not started.
TX Pointer Adjustment - Manual Button
Step
Value
For STS/AU: Select the number of positive (Increment) or negative
(Decrement) pointer adjustments to include into the STS-n (SONET) or
AU-n (SDH):
1
(default) to
1000
. For multiple pointer adjustments, the
pointer adjustment rate is 1 adjustment at every 4 frames.
For VT/TU: Select the number of positive (Increment) or negative
(Decrement) pointer adjustment to include into the VTn (SONET) or
TU-n (SDH):
1
(default) to
1000
. For multiple pointer adjustments, the
pointer adjustment rate is 1 adjustment at every 4 multiframes.
Increment
button sends the positive pointer adjustment defined.
Decrement
button sends the negative pointer adjustment defined.
Pointer Value
indicates the current pointer value.
Summary of Contents for FTB-1
Page 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Page 12: ......
Page 20: ......
Page 22: ......
Page 52: ......
Page 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Page 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Page 84: ......
Page 98: ......
Page 298: ......
Page 574: ......
Page 652: ......
Page 674: ...0 5 1 5 48 5 0 176 W d y K y K D...