![EXFO FTB-1 User Manual Download Page 224](http://html1.mh-extra.com/html/exfo/ftb-1/ftb-1_user-manual_2450042224.webp)
Test Setup - Test Configurator, Timer, and System
212
FTB-700G/800 Series
RFC 2544 - Subtests
Frame Loss Configuration
The objective of this test is to find the percentage of frames that are lost
due to lack of resources. Starting at the specified maximum rate (
Max.
Rate
), the test is performed for a specific frame size and for the specified
duration
(Trial Duration)
. The test is repeated by decreasing the rate by
10 percent, then the test is repeated again until there are two successive
trials in which no frames are lost. The test is performed for each defined
frame size.
Max. Rate
is the maximum rate the test should begin with, in terms of
a percentage of the line rate (
%
),
Mbit/s
, or
Gbit/s
. The accepted
values are as shown in the Max. Rate table on page 209. For
Dual Test
Set
,
Max. Rate
is configurable for both local to remote (
L->R
) and
remote to local (
R->L
) directions.
Trial Duration
represents the time value for each trial in
minutes:seconds:
1
second to
30
minutes (default is
00:01
).
Summary of Contents for FTB-1
Page 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Page 12: ......
Page 20: ......
Page 22: ......
Page 52: ......
Page 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Page 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Page 84: ......
Page 98: ......
Page 298: ......
Page 574: ......
Page 652: ......
Page 674: ...0 5 1 5 48 5 0 176 W d y K y K D...