![EXFO FTB-1 User Manual Download Page 415](http://html1.mh-extra.com/html/exfo/ftb-1/ftb-1_user-manual_2450042415.webp)
Test Results
NetBlazer
403
Summary (Cable Test)
Wire Map Test Result
gives the wire map test result for each pair.
When the link is up: The wire map result for each pair is given as seen
by the FTB-700G/800 Series to get a link up. This means that the wire
map result may not correspond to the type of cable tested depending
on the cable(s) used and/or the configuration of the cable mode (MDI,
MDIX, or auto-detection) on both the FTB-700G/800 Series and the far
end equipment. For example, two crossed pair cables end to end used
between the FTB-700G/800 Series and a far end equipment may give a
straight pair (MDI) wire map result.
Note:
For 1Gbit/s, both MDI and MDIX can be reported simultaneously since
crossed pairs detection is performed independently for pairs A-B and C-D.
MDI
Straight pair.
MDIX
Crossed pair.
MDI (-)
For 1Gbit/s, straight pair with swapped wires within pair.
MDIX (-)
For 1Gbit/s, crossed pair with pair A swapped with pair B and/or pair
C swapped with pair D.
Noise
Excessive noise on a pair most likely caused by a link partner running
in 10/100 Mbit/s forced mode. In this case, no propagation delay or
length is reported and there is no comparison with any threshold.
Summary of Contents for FTB-1
Page 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Page 12: ......
Page 20: ......
Page 22: ......
Page 52: ......
Page 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Page 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Page 84: ......
Page 98: ......
Page 298: ......
Page 574: ......
Page 652: ......
Page 674: ...0 5 1 5 48 5 0 176 W d y K y K D...