Test Results
NetBlazer
343
Alarms/Errors
RDI-P
(Remote Defect Indication - Path)
RX
: Bits 5, 6 and 7 of the G1 byte contain the “100" or “111" pattern in
ten consecutive frames.
TX
: Generates a “100” pattern for bits 5, 6 and 7 of the G1 byte.
LCD-P
(Loss of Code-Group Delineation - Path)
RX
: The signal synchronization has been lost and the valid code-groups
are no longer being delineated from the received payload stream being
passed to the PCS.
TX
: Generates a PCS link down.
LOP-P
(Loss Of Pointer - Path)
RX
: For non-concatenated payloads, a valid pointer is not found in N
consecutive frames (where 8 = N = 10), or N consecutive NDFs
("1001" pattern) are detected.
TX
: Generates a non-valid pointer.
PLM-P
(Payload Label Mismatch - Path)
RX
: Five consecutive frames have mismatched STS signal labels.
UNEQ-P
(Unequipped - Path)
RX
: The C2 byte contains “00 H" in five consecutive frames.
TX
: Generates samples of unequipped STS signal labels (C2 is set to
“00 H”).
ERDI-PSD
(Enhanced RDI - Path Server Defect)
RX
: Bits 5, 6 and 7 of the G1 byte contain the “101” pattern in five to ten
consecutive frames.
TX
: Generates a “101” pattern for bits 5, 6 and 7 of the G1 byte.
Summary of Contents for FTB-1
Page 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Page 12: ......
Page 20: ......
Page 22: ......
Page 52: ......
Page 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Page 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Page 84: ......
Page 98: ......
Page 298: ......
Page 574: ......
Page 652: ......
Page 674: ...0 5 1 5 48 5 0 176 W d y K y K D...