![EXFO FTB-1 User Manual Download Page 341](http://html1.mh-extra.com/html/exfo/ftb-1/ftb-1_user-manual_2450042341.webp)
Test Results
NetBlazer
329
Alarms/Errors
C-FDI
(Client Signal Fail - Forward Defect Indication)
RX
: A CSF frame is received with CSF type equal to
001
.The alarm is
cleared when no CSF (C-FDI) frames are received during an interval
equal to 3.5 times the CSF transmission period indicated in the last
received CSF (C-FDI) frame, or when a CSF frame is received with
Client Defect Clear Indication (C-DCI) information (CSF Type 011).
TX
: Generates a CSF frame with CSF type equal to
001
.
C-RDI
(Client Signal Fail - Remote Defect Indication)
RX
: A CSF frame is received with CSF type equal to
010
. The alarm is
cleared when no CSF (C-RDI) frames are received during an interval
equal to 3.5 times the CSF transmission period indicated in the last
received CSF (C-RDI) frame, or when a CSF frame is received with
Client Defect Clear Indication (C-DCI) information (CSF Type 011).
TX
: Generates a CSF frame with CSF type equal to
010
.
C-DCI
(Client Signal Fail - Defect Clear Indication)
TX
: Generates a CSF frame with CSF type equal to
011
.
Summary of Contents for FTB-1
Page 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Page 12: ......
Page 20: ......
Page 22: ......
Page 52: ......
Page 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Page 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Page 84: ......
Page 98: ......
Page 298: ......
Page 574: ......
Page 652: ......
Page 674: ...0 5 1 5 48 5 0 176 W d y K y K D...