Test Functions
478
FTB-700G/800 Series
Packet Capture
Trigger Position
selects the triggered frame position within the buffer.
Post-Trigger
for a trigger frame located at the beginning of the
buffer. The buffer will contain the triggered frame with the
following frames.
Mid-Trigger
for a trigger frame located at the middle of the buffer.
The buffer will contain the triggered frame with the preceding and
following frames.
Pre-Trigger
for a trigger frame located at the end of the buffer. The
buffer will contain the triggered frame with the preceding frames.
Status and Controls
Capture Status
indicates the status of the data capture:
“--”: The capture is not started and has not run yet.
Armed
...: The capture is started but waiting for the trigger event.
Capturing
...: The capture is in progress. For Post-Trigger and
Mid-Trigger mode, the trigger event has been captured and the buffer is
filling up.
Completed
: The capture is completed.
Frame Count
indicates the number of frames captured that matches
the selected filter criteria. However, for Mid-trigger and Pre-Trigger, the
frame counter will only be available when the capture is completed.
Buffer Usage
indicates the percentage of the buffer capacity used.
Triggered Error
is available when trigger on error is selected and
indicates the error that activated the trigger.
Summary of Contents for FTB-1
Page 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Page 12: ......
Page 20: ......
Page 22: ......
Page 52: ......
Page 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Page 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Page 84: ......
Page 98: ......
Page 298: ......
Page 574: ......
Page 652: ......
Page 674: ...0 5 1 5 48 5 0 176 W d y K y K D...