Test Setup - Test Configurator, Timer, and System
NetBlazer
259
Signal - Signal Configuration (SONET/SDH)
REI-L/MS-REI Computation Method
(OC-192/STM-64 only): Allows to
select the default method used to calculate the REI-L/MS-REI error for
OC-192 and STM-64 signals. Choices are
M1 Only
and both
M0 and M1
.
The default setting is M1 only.
STS/AU and VT/TU Mappings
Timeslot
/
Number
Timeslot
(SONET) allows the selection of the STS timeslot number.
Refer to
information.
Number
(SDH) allows the selection of the AU channel number. Refer
to
on page 631 for more information.
TCM
check box when selected (cleared by default) allows Tandem
Connection Monitoring (TCM).
TC-UNEQ-P / TC-UNEQ-V / HPTC-UNEQ / LPTC-UNEQ
check boxes
when selected (cleared by default) allows the monitoring of the
corresponding Tandem Connection - Unequipped alarm. Only
available when the
TCM
check box is selected.
Overwrite Fixed Stuff
(STS-1 only) check box when selected (default)
fills up the bytes of the STS-1 SPE’s columns 30 and 59 with the
selected pattern from the tab
Background Traffic
allows the selection of the high order path
background traffic:
AIS
,
Equipped
(PRBS23) - (default), or
Unequipped
.
Summary of Contents for FTB-1
Page 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Page 12: ......
Page 20: ......
Page 22: ......
Page 52: ......
Page 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Page 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Page 84: ......
Page 98: ......
Page 298: ......
Page 574: ......
Page 652: ......
Page 674: ...0 5 1 5 48 5 0 176 W d y K y K D...