![EXFO FTB-1 User Manual Download Page 234](http://html1.mh-extra.com/html/exfo/ftb-1/ftb-1_user-manual_2450042234.webp)
Test Setup - Test Configurator, Timer, and System
222
FTB-700G/800 Series
S-OAM and MPLS-TP OAM
Pass/Fail Verdict
Pass/Fail Verdict
check box when selected (default) enables the use of the
pass/fail verdict. A global fail verdict is declared when any of the following
condition is met:
Link Down
alarm,
Loss Continuity
alarm, or any fail
verdict for
Frame Delay
,
Frame Loss
,
Synthetic Loss
(Only applicable to
Ethernet OAM),
Frame Delay Failure
,
Frame Loss Failure
,
Synthetic Loss
Failure
(Only applicable to Ethernet OAM),
Loopback Failure
, or
Test
Failure
.
Thresholds
Available with G.8113.1, Y.1731 and MEF OAM Modes when Pass/Fail verdict
is enabled. The verdict is PASS when the measured value is lower or equal
to the threshold value.
Frame Delay Threshold (ms)
allows to set the threshold value of
frame delay:
0.001
to
8000
ms (default is
50
ms).
Frame Loss Threshold (%)
allows to set the threshold value of frame
loss:
0.001
to
100
% (default is
10
%).
Synthetic Loss Threshold (%
), available with Ethernet OAM (Y.1731
and MEF), allows to set the threshold value of Synthetic Loss:
0.001
to
100
% (default is
10
%).
Summary of Contents for FTB-1
Page 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Page 12: ......
Page 20: ......
Page 22: ......
Page 52: ......
Page 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Page 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Page 84: ......
Page 98: ......
Page 298: ......
Page 574: ......
Page 652: ......
Page 674: ...0 5 1 5 48 5 0 176 W d y K y K D...