![EXFO FTB-1 User Manual Download Page 198](http://html1.mh-extra.com/html/exfo/ftb-1/ftb-1_user-manual_2450042198.webp)
Test Setup - Test Configurator, Timer, and System
186
FTB-700G/800 Series
Network
IP
IP Version
allows the selection of either
IPv4
(default) or
IPv6
. Only IPv4 is
supported for TCP Throughput test application.
For
IPv4
the following configuration parameters are available.
Automatic IP (DHCP)
check box, when selected (cleared by default),
allows to dynamically obtain an IP address from a DHCP (Dynamic
Host Configuration Protocol) server.
IP Address
1
: Enter the IP address of the port. The default setting is
10.10.x.y, where x and y are respectively the two least significant bytes
of the port default MAC address.
Subnet Mask
: Enter the Subnet Mask. The default setting is
255.255.000.000
.
check box, when selected (cleared by default),
allows to enter a default Gateway IP address. When the
Default
Gateway
check box is selected, its default address is
0.0.0.0
.
1. Not configurable when the
Automatic IP (DHCP)
check box is selected.