![EXFO FTB-1 User Manual Download Page 211](http://html1.mh-extra.com/html/exfo/ftb-1/ftb-1_user-manual_2450042211.webp)
Test Setup - Test Configurator, Timer, and System
NetBlazer
199
Network Details (iSAM)
Each profile entry has the following parameters.
Profile Name
: 1 to 16 characters. All ASCII characters from 32 to 126
decimal are supported.
Frame Type
: Enter
Fixed
or
EMIX
. When the frame type is missing
from a profile,
EMIX
is used.
Frame Size
on page 195 for possible values); when
the frame size is missing from a profile, default value(s) is used:
For
Fixed
: Enter a unique frame size.
For
EMIX
: Enter 2 to 8 frame sizes with a comma between each entry.
VLAN Priority
1
(optional): Enter the priority number.
DSCP
(optional): Enter either the DSCP name or its binary value.
Performance Criteria
: Enter the name of the performance criteria.
When the
Performance Criteria
is missing from a profile or is not
available from the user profile file, the
User Performance
criteria is
used.
When a parameter is missing from a profile, the default value of the
missing parameter is used.
The value of a parameter is validated to ensure it is within the supported
range; otherwise the profile entry is unsupported.
If the profile file contain more than 25 profiles, only the first 25 valid profiles
are retained.
1. See
Summary of Contents for FTB-1
Page 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Page 12: ......
Page 20: ......
Page 22: ......
Page 52: ......
Page 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Page 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Page 84: ......
Page 98: ......
Page 298: ......
Page 574: ......
Page 652: ......
Page 674: ...0 5 1 5 48 5 0 176 W d y K y K D...