Test Setup - Test Configurator, Timer, and System
218
FTB-700G/800 Series
RFC 6349
CIR
The Local-to-Remote CIR and Remote-to-Local CIR represent the
Committed Information Rate of the Ethernet Service under test:
1.0 Mbit/s
to Line Rate. The CIR is not used to actually transmit frames
at this rate but to calculate a Bandwidth Delay Product (BDP) which in
turn is used to set the Max Window Size of the TCP connections.
Rate Unit
determines the unit used to display the rate values:
Mbit/s
(default) or
Gbit/s
.
TOS/DS
(IPv4) allows to enter an hexadecimal value,
00
(default) to
FF
. Changing the
IP TOS/DS
value will affect the
TOS/DS Config
settings and vice versa.
MTU
Max MTU (bytes)
determines the Maximum Transfer Unit (MTU) to
use when the client is generating TCP traffic toward the server: from
1080
to
1500
bytes (default).
Path MTU Discovery
check box when selected (default) allows to
perform a Packetization Layer Path MTU Discovery phase.
Window Sweep
Window Sweep
check box when selected (default) allows to perform
the Window Sweep phase.
Duration (per step)
is the duration of the Window Sweep phase per
direction and per Window tested: 30 seconds (default) to 5 minutes.
Summary of Contents for FTB-1
Page 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Page 12: ......
Page 20: ......
Page 22: ......
Page 52: ......
Page 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Page 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Page 84: ......
Page 98: ......
Page 298: ......
Page 574: ......
Page 652: ......
Page 674: ...0 5 1 5 48 5 0 176 W d y K y K D...