Test Setup - Test Configurator, Timer, and System
224
FTB-700G/800 Series
S-OAM and MPLS-TP OAM
MEG Level
(Y.1731, MEF, and G.8113.1) is the Maintenance Entity
Group Level configurable from
0
to
7
(default).
MD Level
(802.1ag) is the Maintenance Domain Level and is
configurable from
0
to
7
(default).
MEP ID
is the Maintenance Entity Group End Point Identification
configurable from
0x0001
(default) to
0x1FFF
.
Peer MEP Parameters
MAC Address
, available with S-OAM Mode, allows to enter the unique
Media Access Control (MAC) address of the peer MEP (default is
00:00:00:00:00:00
).
MEP ID
is the Maintenance Entity Group End Point Identification
configurable from
0x0001
(default) to
0x1FFF
.
OAM Quick Ping
verifies the bidirectional connectivity with the peer
MEP. The
Successful
message is reported when at least one of three
attempts has been successful otherwise
Failed
is reported.
Continuity Check
CC Function
check box when selected (default) allows to transmit and
monitor CCM frames.
The following parameters are only configurable when the
CC Function
check box is cleared.
Address Type
, available with S-OAM Mode, defines the destination
address type of the CCM frames:
Unicast
or
Multicast
(default).
Priority
, available with S-OAM Mode or when VLAN is enabled (see
on page 190), allows to select the VLAN user priority:
0
to
7
information.
Summary of Contents for FTB-1
Page 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Page 12: ......
Page 20: ......
Page 22: ......
Page 52: ......
Page 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Page 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Page 84: ......
Page 98: ......
Page 298: ......
Page 574: ......
Page 652: ......
Page 674: ...0 5 1 5 48 5 0 176 W d y K y K D...