Test Setup - Test Configurator, Timer, and System
190
FTB-700G/800 Series
Network
VLAN
VLAN Tag
check box, when selected (cleared by default), enables and
allows to set up to 3 stacked VLANs.
For each VLAN tag enabled, C-VLAN / S-VLAN / E-VLAN, the following
parameters are configurable.
VLAN ID
choices are
0
through
4095
; refer to
page 639 for more information.
Priority
, VLAN user priority, choices are
0
(default) to
7
on page 639 for more information.
Type
, VLAN Ethernet Type, choices are
0x8100
(default for C-VLAN),
0x88A8
(default for S-VLAN),
0x9100
(default for E-VLAN),
0x9200
,
and
0x9300
.
Drop Eligible
, when set to
Yes
(DEI = 1), the transmitted frames will
be dropped first on receipt when congestion occurs under test. Drop
Eligible is not available when VLAN type is 8100. This setting is set to
No
by default.