Simply select a colour pair and daisy chain together as follows:-
IMPORTANT - Bus Termination Rules
RS232 CAN Converter
The first and last systems in the chain should have a 120 ohm resistor connected across the 2 pin terminal block
(CAN High and CAN Low pins). The systems in the middle of the chain all other systems do not require a resistor.