V3.5 14/08/19
UD0089
Page 739
This Document is uncontrolled unless over stamped "CONTROLLED DOCUMENT"
4.9
EMERGENCY IFOB RELEASE
4.9.1
EMERGENCY IFOB RELEASE
The Emergency iFob Release utility is available to release all the iFobs from a system one at a time.
1.
Using the Master Key, unlock the Pod Lock. The Control Panel is hooked in at the bottom and locked at
the top. Carefully begin to open the Control Panel.
2.
Hold down the * key on the keypad. At the same time press and release the Reset button on the Control
PCB.
NOTE:
If you are running v6.06.12 or below of the firmware you will not get a menu and the
system will open the door (if fitted) and start to release each iFob one at a time for 5 seconds
starting at position 1 and will continue to do so until the door is closed. Empty slots will be
skipped.
3.
Close the Control Panel carefully into the Pod and lock with the Master Key.
The Control Panel should fit easily, if not check that no wires have become caught or trapped between the
Control Panel and the Pod.
4.
Use the keypad to navigate through the menus...
Press 1 to release all the iFobs.
The door will open (if fitted).
If you have more than one cabinet attached to your system you will be asked to select which door
you want to open, simply enter the door number on the keypad.
The Traka System will release each iFob one at a time for 5 seconds starting at position 1 and will
continue to do so until the door is closed. Empty slots will be skipped.
Press 2 to release a specific iFob.
You will be prompted to enter the position number of the iFob that you wish to release. Using the
keypad, enter the position number followed by #.
If you have a fixed return system, the appropriate door will open automatically. If you have a
Random Return system with more than one cabinet you will be asked to select which door you want
to open, simply enter the door number on the keypad.
The Traka System will release the specified iFob until the door is close or the system times out.
To release another iFob, simply close the door and repeat step 4.
Press * to exit.
5.
Simply remove the iFob from the position; you do not need to press the black button next to the iFob.
6.
When you have finished simply close the door.