Using Fixed Return to Multiple Systems
Now that the iFob record has been duplicated and Traka32 knows the iFob can be used at both cabinets, view the
second system within Traka32 and you will notice that there will be a greyed out iFob in the position that you selected
to host your duplicate iFob. Traka32 now recognizes that there should be an iFob in that position but it is currently out
of the system.
Take the iFob from your first cabinet and place it in the newly assigned position in the second cabinet, Read all System
Data and the iFob will appear in that slot. Traka32 and the cabinets will function as normal.
Hide Duplicate iFob Status
When iFobs are removed from a system with LEDs, the LED for that position will illuminate orange to show that the
logged in user currently has the iFob. However, when using Fixed Return To Multiple Systems the iFob could be
removed from System 1 and placed in System 2. The LED will still illuminate orange when the user logs in to System 1
when in actual fact they no longer have the iFob in their possession.
To overcome this, an option to Hide Duplicate iFob Status is available from the Configure Firmware menu. This option
will hide the 'Held' status LED (orange) of duplicated iFob positions only. LEDs will function as normal on all non-
duplicated positions.
1.
From the System Viewer page right click the Control Pod and select Configure Firmware.
2.
Click Next through the pages until you reach the page shown below. The option for Hide Duplicate iFob
Status is highlighted.
3.
Select this option and click Next until you reach the final page, then click Apply. The change will be applied
to the system. Repeat this process for each of the systems.