V3.5 14/08/19
UD0089
Page 800
This Document is uncontrolled unless over stamped "CONTROLLED DOCUMENT"
4.15.2
CONFIGURING THE GSM MODULE
Before using the GM28 or GM29 module, the module will need configuring using Traka32 and a standard serial cable.
NOTE:
If the unit was supplied by Traka, this configuration will already have been done at the factory.
1.
Insert a SIM Card into the SIM Holder on the Sony Ericsson GM28 or GM29 module.
2.
Connect a standard serial cable from the 9 PIN D-Sub on the Sony Ericsson GM28 or GM29 module to a spare
serial port on a PC with Traka32 installed.
3.
Connect the Power connector of the Sony Ericsson GM28 or GM29 module to a Traka Control PCB and power
up the unit.
4.
Load Traka32 (use the 'Traka Engineer' login if required)
5.
Click on Engineers, Diagnostics and the diagnostics window will open.
6.
Click on the Serial Tab.
7.
Set the Serial Port Number as required.
8.
Set the serial port settings to 9600,N,8,1.
9.
Click on the Traka toolbar menu item to toggle it to Dumb.
10.
Click on the Clear toolbar menu item to clear the main screen.
11.
Click on Connect.
12.
From the main screen type the following...
a.
Type at+ifc=0,0 followed by Enter and you should see OK appear.
b.
Type at+ipr=19200 followed by Enter and you should see OK appear on the next line.
13.
Click on Disconnect.
14.
Set the serial port settings to 19200,N,8,1.
15.
Click on the Clear toolbar menu item to clear the main screen.
16.
Click on Connect.
17.
From the main screen type the following...
a.
Type at+cpin="1234" followed by Enter and you should see OK appear.
NOTE:
'1234' is the SIM Card's PIN.
b.
Type at+cgsms=3 followed by Enter and you should see OK appear.
c.
Type at+cmgf=1 followed by Enter and you should see OK appear.
d.
Type at+csdh=1 followed by Enter and you should see OK appear.
e.
Type at+csdh=1 followed by Enter and you should see OK appear.
f.
Type at+csmp=17,167,0,0 followed by Enter and you should see OK appear.
g.
Type at+cnmi=3,2,2,1 followed by Enter and you should see OK appear.
h.
Type at&w followed by Enter and you should see OK appear.
18.
Click on Disconnect.
19.
Close the Diagnostics window.