3.19.7.2
FIRE ALARM ACCESS OVERRIDE OPERATION
NOTE:
Fire Alarm Access Override is a firmware cost option; please ensure the correct firmware is loaded
prior to using the system.
1.
If the system detects an input from the fire alarm or break glass switch, the system LCD will display:
2.
The door will open and the solenoids will fire in-turn starting from position 1. A user will be able remove the
iFob indicated by the LCD:
...
And so on...
NOTE:
The user is not required to press the button to remove the iFob because the solenoid is
released automatically. Simply pull the iFob to remove it from the slot.
3.
When the system detects the fire alarm or break glass switch has been reset, the system will return to normal
operation. The LCD will briefly display the following:
Fire Alarm Access Override Events
The Traka system records 2 system events related to the Fire Alarm system viewable from the Traka 32 software:
Fire Alarm Activated (code 60)
Recorded when the system detects the fire alarm or break glass has been activated.
Fire Alarm Ended (code 61)
Recorded when the fire alarm has been reset indicating the system can return to normal operation.
For details on the all Event Codes please refer to the Alarm & Event Types.
For more information please view the following sections:
Fire Alarm Access Override Overview