Human Interface Type
Select the Human Interface Device (HID) Type used for access. For example an RFID card or tag
would be placed within "proximity" of the reader and a magstripe card would be "swiped" through the
reader.
NOTE:
This settings has no effect on how the data is decoded; it simply updates the LCD
scrolling text accordingly.
Number of bits / bytes to process
Enter the number of bits to process for a Wiegand reader or enter the number of bytes to decode for
the either an RS-232, Barcode or NEDAP Access Control reader.
For example, for a Wiegand 26bit card you would be 26 bits.
Number of bits / bytes to decode
Enter the number of bytes to decode for either an RS-232 or NEDAP Access Control reader or
enter the number of digits required for the PIN on a Keypad Only or Biometrics (TSSI) reader.
Card Section Count
Select the number of sections of data to decode from a Clock & Data, Wiegand or Barcode reader.
The selected number of sections (1 to 4) will enable the relevant number of section settings below.
Wiegand Buffer Base (bits)
This field shows the maximum base size of the Wiegand buffer. This value can be used for calculating
the Card Section Starts.
Card Section Start
Enter the start bit or byte for this section.
Card Section Length
Enter the number of bits or bytes within this section to decode.
Card Section Offset
Enter the number of characters to offset the result by.
Card Reader Code
The card reader code can be used with a Wiegand reader to display the current configuration in a
string.