NOTE:
This indicates it has been loaded into the Traka32 database only at this stage and not yet
applied to the cabinet.
If the configuration file was incorrect, check that you have the correct file via the file name and try again. An
incorrect file may be may be because…
a.
The CPSN did not match,
b.
The Hardware Key did not match or,
c.
The Firmware Version did not match.
7.
Follow the wizard through, checking ALL the settings and amend as required. For details on the various
settings, please refer to the
8.
Finally click on Apply to load the configuration into the cabinet.
If you wish you may also save the current configuration (with any changes) to a File. Click on
to do so and provide a suitable name for the file perhaps indicating any specific options
that it contains.
9.
Now that the new 16bit Control PCB’s CPSN has been registered, you will be able to communicate as normal.