V3.5 14/08/19
UD0089
Page 613
This Document is uncontrolled unless over stamped "CONTROLLED DOCUMENT"
8.
When you have synchronised each system, select the first system from the system dropdown and then click
the Read Selected System Data button as highlighted below.
9.
Repeat step 8 for each system in order.
NOTE:
It is very important that you read the system data in the order in which the iFob Tags are
allocated.
10.
From the Traka32 software’s System Viewer, right click over the picture of the system and click on
Engineers>Synchronise iFobs. This will write the assigned iFob Indexes into the Data iFobs memory which
can then be used for iFob Searching.
11.
Repeat step 10 for each system.
12.
Once assigned, we would normally recommend that you attached a tag to each iFob displaying the iFob’s
Index number for easy reference. Please refer to the next sections for details on how to assign the iFob tags.
Automatic Tag Numbering (Optional)
IF you wish to have tag numbers you can auto allocate them within the software. This option allows the tag number to
be allocated automatically when they are added to the system. For example, if you have 10 iFobs in your system with
tag numbers 1-10 and you delete iFob 2 (along with its tag number) and replace it with another iFob, when you assign
that new iFob to the system accordingly, it will be given tag number 2 automatically. This option is particularly
beneficial to customers who already have RRMS and wish to add another system without manually selecting the new
tag numbers. This feature is compatible with 8bit & 16bit.
To enable this option click File>Properties and select the General tab. You will see a small box named Auto
Allocate Tag Numbers, tick this box. You will also notice there is a Select Tag Start Number section, this allows
you to select a specific number your tags will start from. If you leave this section blank the tag numbers will start at 1
by default. After choosing the appropriate settings you can Save and Close.
Manual Tag Numbering (Optional)
Manual tag numbering can be done at any stage after the iFobs have been Reset or synchronised to the system,
whether or not the system is RRMS, RRSS or a standard Fixed return. For Example, if you require a RRMS then you
will need to follow the procedure below for resetting the iFobs and synchronising the system before you can manually
select iFob tag numbers. However if you are using standard system then you will need to synchronise the iFobs as
normal before being able to manually selecting iFob numbers.