V3.5 14/08/19
UD0089
Page 753
This Document is uncontrolled unless over stamped "CONTROLLED DOCUMENT"
6.
Using the Master Key release the door (if fitted) using the Door Release Lock.
7.
Using a 4mm Allen Key, remove the cover panel screws one at a time and remove the cover panels.
8.
Using a large flat bladed screwdriver, carefully remove the screws from the blank receptor strip above the
receptor strip you wish to release the iFobs from. Remove the strip and spacers and place to one side.
9.
Again using a large flat bladed screwdriver, carefully remove the screws from the receptor strip you wish to
release the iFobs from. Remove the strip carefully disconnecting the receptor ribbon cable.
10.
Using a small flat blade screwdriver, you will be able to pull back the small solenoid blade that holds the iFob
in place and remove the iFob.
11.
Repeat steps 9 to 11 for each receptor strip you wish to remove the iFobs from.
NOTE:
It is essential that the receptor strips are replaced in the same location from which they
were removed otherwise the system will not function correctly.
12.
When you have released the iFobs replace all the receptor strips reconnecting the receptor ribbon cable.
Using a large flat bladed screwdriver secure the receptor strips in place with the fixings and spacers removed
earlier.
13.
Using a 4mm Allen Key, replace the cover panels one at a time. Note the cover panels are handed. Once the
cover panels have been replaced then close the door (if fitted).
14.
Please contact your supplier to have your Traka System repaired and tested.