4.9.3
MANUAL IFOB RELEASE
4.9.3.1
M-SERIES MANUAL IFOB RELEASE
In the event of total system failure you will need to remove various parts of the M-Series Traka System to gain access
to the iFobs / Keys.
Tools required...
Large flat blade screwdriver
Small flat blade screwdriver
4mm Allen Key
1.
Switch off the mains power to the unit by removing the fuse from the fused spur or unplugging from the
mains.
2.
The Control Panel is hooked in at the bottom and locked at the top. Using the Master Key, unlock the Cam
Lock.
3.
Lean the Control Panel forward and set the On/Off switch on the Control PCB to Off.
4.
Reach inside and open the door manually by moving the
5.
Carefully close the Control Panel.