V3.5 14/08/19
UD0089
Page 195
This Document is uncontrolled unless over stamped "CONTROLLED DOCUMENT"
NOTE:
Use with caution! Resetting the biometrics reader will reset the reader's entire memory. As
part of the reset procedure it will request that you backup the templates before the restoring. To
backup the templates, first click on Yes. Once successfully backed up, you will be prompted to reset
the templates, to reset click on Yes.
NOTE:
Traka will not be held responsible for the loss of data if you do not backup the templates
before resetting.
Engineers
NOTE:
This menu can only be accessed if the current user of the software is logged in as an engineer.
Synchronise Users
This synchronises all the user records in the database with a specific system. If you want to synchronise all the
user records in the database with all the systems, this can be done from the
Synchronise iFobs
This reads all the iFob serial numbers, creates new iFob records in the database for any unrecognised iFobs
found and then synchronises all the iFob records in the database with the selected system.
Synchronise Key Bookings
This synchronises all the key bookings in the database with the selected system.
NOTE:
This option will only show if the firmware of the selected system has Key Booking enabled.
Reset System
This option should be used with great caution! It deletes the information held with the system and resets the
Traka system memory. The reset procedure will first prompt you to backup the systems memory. It will then
reset the systems entire memory.
NOTE:
Use with caution! Resetting the system will reset the systems entire memory. As part of the
reset procedure it will request that you read the system data before the resetting. To read the data
first click on Yes. Once successfully read, you will be prompted to reset the system, to reset click on
Yes.
NOTE:
Traka will not be held responsible for the loss of data if you do not read the system data
before resetting.