background image

EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN

Operating instructions 

Additional languages www.r-stahl.com  

EN

Explosion Proof Combination Signal - 

110 dB (A) / 5 Joule

Series YL60

Summary of Contents for YL60 Series

Page 1: ...EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Operating instructions Additional languages www r stahl com EN Explosion Proof Combination Signal 110 dB A 5 Joule Series YL60 ...

Page 2: ... design 6 4 1 Function 6 5 Technical data 7 6 Transport and storage 9 7 Mounting and installation 10 7 1 Dimensions fastening dimensions 10 7 2 Mounting dismounting operating position 11 7 3 Installation 21 8 Commissioning 21 9 Operation 22 9 1 Troubleshooting 22 10 Maintenance overhaul repair 22 10 1 Maintenance 23 10 2 Repair 23 10 3 Returning the device 24 11 Cleaning 24 12 Disposal 24 13 Acces...

Page 3: ...sh edition They are legally binding in all legal affairs 1 3 Further documents Data sheet For documents in additional languages see www r stahl com 1 4 Conformity with standards and regulations See certificates and EU Declaration of Conformity www r stahl com The device has IECEx approval For certificate please refer to the IECEx homepage http iecex iec ch 2 Explanation of the symbols 2 1 Symbols ...

Page 4: ...ION NOTICE Type and source of danger damage Consequences of danger Taking countermeasures to avoid the danger or damage Strobe Sounder Earth Sounder Tone Telephone initiate DANGER Danger to persons Non compliance with the instruction results in severe or fatal injuries to persons WARNING Danger to persons Non compliance with the instruction can result in severe or fatal injuries to persons CAUTION...

Page 5: ...evice Use the device in accordance with its intended and approved purpose only We cannot be held liable for damage caused by incorrect or unauthorized use or by non compliance with these operating instructions Before installation and commissioning make sure that the device is not damaged Work on the device installation maintenance overhaul repair may only be carried out by appropriately authorized...

Page 6: ...dous or harsh environments In hazardous areas the devices have explosion protection for ATEX IECEx Zones 1 2 for gas and 21 22 for dust Gas groups covered are IIB IIB H2 dust protection for IIIC UL certified variants offer protection to Class I Division I Gas groups BCD Class II Division I Gas groups EFG The device is not intended for continuos use The life of the xenon flash tube is guaranteed fo...

Page 7: ...IB H2 EII 2 G Ex d IIB H2 T4 Gb Ta 20 60 C EII 2 D Ex tb IIIC T135 C Db IP 66 Ta 20 60 C EII 2 G Ex d IIB H2 T6 Gb Ta 20 40 C EII 2 D Ex tb IIIC T85 C Db IP 66 Ta 20 40 C IIB EII 2 G Ex d IIB T4 Gb Ta 35 60 C EII 2 D Ex tb IIIC T135 C Db IP 66 Ta 35 60 C EII 2 G Ex d IIB T6 Gb Ta 35 40 C EII 2 D Ex tb IIIC T85 C Db IP 66 Ta 35 40 C IIB H2 IIB E161818 E188831 IIB H2 IIB SL UL 60079 0 UL 60079 1 UL ...

Page 8: ... Electrical data Rated operational voltage 24 V DC 48 V DC 115 V AC and 230 V AC operational parameters or 10 Rated operational current Mechanical data Material Enclosure aluminium seawater resistant Horn ABS flame retardant Lens cover polycarbonate Fixings stainless steel Cable entries 2 cable entries equipped with stopping plug 1x and dust cap 1x UL devices equipped with M20 1 2 adapters 2x Degr...

Page 9: ...d storage Transport and store the device only in the original packaging Store the device in a dry place no condensation and vibration free Do not drop the device Acoustic data Volume 110 dB A 1 m Polar diagram Luminous characteristics Effective candela Candela seconds Flash energy 5 J Flash rate 60 FPM Technical Data Horizontal plane Vertical plane 15288E00 5 J Clear 46 cd Yellow 42 cd Amber 28 cd...

Page 10: ...EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Explosion Proof Combination Signal 110 dB A 5 Joule Series YL60 7 Mounting and installation 7 1 Dimensions fastening dimensions Dimensional Drawings All Dimensions in mm inches Subject to Alterations 18380E00 ...

Page 11: ... joint surfaces must not be damaged and must be protected from dust and dirt Install the end flanges squarely without applying any force Do not use a hammer or other tools when working on the flanges and do not use the fixing screws to pull down the flanges DANGER Explosion hazard Risk of injuries and material damage Only use cable glands with corresponding certificate The cable glands must be fla...

Page 12: ... 2 Access to the PCB Remove the 3 screwST 4 2 x 13 Lift horn cover Remove the 4 cheese head screws M5 x 16 Lift sounder flange Disconnect pressure unit from PCB see Electrical Connection Key Components Lift PCB to expose terminals for connection see Electrical Connection Wiring Diagrams for details 15256E00 1 Screws ST 4 2 x 13 2 Horn cover 3 Cheese head screws M5 x 16 4 Sounder flange 5 PCB 6 Enc...

Page 13: ...enclosure Do not clamp in any cables in the process Insert the horn flange in a straight position without applying any pressure Replace cheese head screws M5 x 16 see information below and tighten the screws with a tightening torque of 3 Nm Re attach the cover Tighten the ST 4 2 x 13 screws with a tightening torque of 0 4 Nm 18814E00 18813E00 YL60 D50 YL60 F50 YL60 L50 YL60 N50 Carefully assemble ...

Page 14: ...ents YL60 AC Legend 7 Terminal blocks 8 Connector for sounder 9 Tone selection switch ton table 10 Link for combined function DC version only 15266E00 Link connected Strobe and sounder work together Link removed Strobe and sounder independent function Strobe Sounder Approximately 20 cm 8 Inch tails are required inside the enclosure for connection to the terminals on the PCB This is especially impo...

Page 15: ...ed function of sounder and strobe with one signal tone Connection to a 2 wire conductor Combined function of sounder and strobe with two signal tones Connection to a 3 wire conductor Line monitoring for devices with DC Through reverse polarity By connecting an EOL resistor between 0 V and V The resistance value is defined by the system developer Two signal levels for devices with DC Through revers...

Page 16: ...n to a 4 wire conductor Combined function of sounder and strobe activation by telephone signal Sounder and strobe are activated by a telephone signal The function is retained as long as the telephone signal is available The strobe can flash up to four times after deactivating the telephone signal Tone 1 Tone 2 18403E00 18404E00 15266E00 Remove jumper from LK1 and LK2 18401E00 Connection Strobe TB1...

Page 17: ...AC version Combined function of sounder and strobe with one signal tone Connection to a 2 wire conductor Combined function of sounder and strobe with two signal tones Connection to a 3 wire conductor Independent function of sounder and strobe Connection to a 3 wire conductor 18414E00 Bridge TB1 and TB2 using a conductor Tone 1 Tone 2 18408E00 18407E00 18406E00 Second tone via connection to TB4 pos...

Page 18: ...ated by a telephone signal The function is retained as long as the telephone signal is available The strobe can flash up to four times after deactivating the telephone signal 7 2 5 Earth connection The unit must be connected to a good quality earth The internal Earth connection is the primary point The external connection is for a supplementary bonding connection and is used where local code or au...

Page 19: ... Alternate fast two tone 800 1000 10111 0 25 Increased urgency Level crossing Tone 04 Alternate fast two tone 2500 3100 00111 0 25 Security deterrent Tone 05 Alternate two tone 440 554 11011 0 4 0 1 AFNOR France Tone 06 Alternate two tone 430 470 01011 1 0 Tone 07 Alternate very fast two tone 800 1000 10011 0 13 Tone 08 Alternate very fast two tone 2500 3200 00011 0 07 Tone 09 Alternate two tone 4...

Page 20: ... 0 3 Industrial alarm Germany Tone 25 Interrupted fast rising volume 1400 11100 0 25 Tone 26 Fast siren 250 1200 01100 0 085 Tone 27 Rising constantly falling 1000 10100 10 40 10 Industrial alarm Germany Tone 28 ISO 8201 Evacuation 800 1000 00100 As standard International evacuation alarm Tone 29 Fast whoop 500 1000 11000 0 15 Tone 30 Slow whoop 500 1200 01000 4 5 Evacuation The Netherlands Tone 3...

Page 21: ...regulations WARNING Danger of electric shock due to energised parts Non compliance can result in severe or fatal injuries All connections and wiring must be disconnected from the power supply Secure the connections against unauthorized switching DANGER Explosion hazard Risk of injuries and material damage Operate the device only if it is not damaged If the thread is damaged the device must be repl...

Page 22: ... this document If the error cannot be eliminated using the mentioned procedures Contact R STAHL Schaltgeräte GmbH For fast processing have the following information ready Type and serial number Purchase information Error description Intended use in particular input output wiring 10 Maintenance overhaul repair WARNING Risk of electric shock or malfunctioning of the device due to unauthorized work N...

Page 23: ...ambient temperature or falling below the device must be taken out of operation the enclosure components for formation of cracks and damage Replace the exchangeable enclosure components If the enclosure components are non exchangeable the device must be taken out of operation its intended use If the device is not used according to its intended use it must be taken out of operation if the conductors...

Page 24: ...ice Send the device along with the RMA slip in the packaging to R STAHL Schaltgeräte GmbH refer to Section 1 1 for the address 11 Cleaning Clean the device only with a cloth brush vacuum cleaner or similar items When cleaning with a damp cloth use water or mild non abrasive non scratching cleaning agents Do not use aggressive detergents or solvents 12 Disposal Observe national and local regulation...

Page 25: ......

Page 26: ......

Reviews: