13.
Click on the Comms tab.
14.
You will see a Comms Type drop down menu. From this you can select:
a.
b.
c.
15.
Select the appropriate communication setting.
16.
If you have chosen Serial, select the following options:
a.
Serial Port
Select the Serial Port of the PC that you have connected the Traka System to.
b.
Serial Port Settings
Select the appropriate serial port settings.
For an 8bit system the setting depends upon the type of crystal your Traka system has been fitted
with. Set 9600,N,8,1 if the 8bit Control PCB is fitted with a 3MHz crystal or set 19200,N,8,1 if the
8bit Control PCB is fitted with a 7MHz crystal. Please refer to the
locate crystal type.
For a 16bit system the default setting is 38400,N,8,1. The 16bit hardware can also be configured
for 19200,N,8,1 or 9600,N,8,1 if required.