Include In Auto Comms
Tick this option if you want to include the system in the ’Auto Communication’ group.
Nominate a PC
Tick this option to nominate a PC or Server to Auto Communicate with this system.
PC Name, IP or IP Name
Enter the PC Name, IP or IP Name of the nominated PC. Only the nominated PC will attempt to Auto
Communicate with the selected System. If nominate a PC is left un-ticked, then any copy of Traka 32
set for auto-communications will attempt to communicate with the selected system.
System Integration
Timecon Access Control
Timecon Access control allows the potential of integration of access control systems to the Traka system.
A typical example is where an access control reader would be attached to the Traka System. The reader would
be connected to an access control system. When a card is swiped at the reader, the card data would be sent
directly to the access control system. The access control system would verify the user and record the fact that a
card was swiped. If the card is valid, the access control system would send a packet of data containing details
of the user via TCP/IP to the Traka32 software. Traka32 would decode the incoming packet, again verify the
user details and if valid would send a command to the Traka System to open the door.
Please contact Traka for full details.
Siemens Fire Control
Siemens Fire control allows the potential of integration of fire control systems to the Traka system.
A typical example is where certain iFobs/items need to be released when a fire alarm is raised. In the event of a
fire alarm, the fire control system would send a packet of data containing details of the alarm number and
associated iFobs/items via TCP/IP to the Traka32 software. Traka32 would decode the incoming packet and if
valid would send a command to the Traka System priming it to release the iFobs/items when the fire
department accesses the Traka System.