Multi-Frequency

Quad Photobeam Detectors

E-964-Q660Q–

660 ft. (200m) outdoors, 1320 ft. (400m) indoors

E-964-Q495Q–

495 ft. (150m) outdoors,   990 ft. (300m) indoors

E-964-Q330Q–

330 ft. (100m) outdoors,   660 ft. (200m) indoors

E-964-Q165Q–

165 ft. (  50m) outdoors,   330 ft. (100m) indoors

®

ENFO

RCER

SENSOR

MANUAL

SECO-LARM

®

Summary of Contents for ENFORCER E-964-Q165Q

Page 1: ...rs E 964 Q660Q 660ft 200m outdoors 1320ft 400m indoors E 964 Q495Q 495ft 150m outdoors 990ft 300m indoors E 964 Q330Q 330ft 100m outdoors 660ft 200m indoors E 964 Q165Q 165ft 50m outdoors 330ft 100m indoors ENFORCER SENSOR MANUAL SECO LARM ...

Page 2: ...Detail 8 BeamAlignment Template 8 BeamAlignment 9 Adjusting the Response Time 10 Testing the Unit 10 Specifications 10 Dimensions 11 Troubleshooting 11 Introduction The ENFORCER E 964 Q Series Quad Photobeam Sensors are ideal for long distance protection Four selectable beam frequencies allow for superior perimeter protection by eliminating crosstalk and interference between multiple units False a...

Page 3: ...der for alignment Vertical adjustment screw Green power LED Power 12 24V AC DC Alarm output Beam strength indicator 5 LEDs Tamper output Voltage output probes Vertical adjustment screw Alignment laser On Off switch for laser On Off switch for laser Alignment laser Receiver shown IMPORTANT Do not connect to power until the sensor is completely installed and the installation has been double checked ...

Page 4: ...mperoutput N C switch 1A 30VDC Max 7 6 Power AC DC 12 24V non polarity 2 1 Running the Cable Run a cable from the alarm control panel to the photobeam sensor If burying the cable is required make sure to use electrical conduit Shielded cable is strongly suggested See Table 1 for maximum cable length Table 1 Cable Length Note 1 Max cable length when two or more sets are connected is the value shown...

Page 5: ... Tx Rx Rx Tx Rx Tx Channel 4 Channel 1 Channel 2 SECO LARM U S A Fig 3 Typical Installations Side Views Top Views 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 1234 1234 1234 1234 1234 1234 1...

Page 6: ...fig 4 2 If the sensor wiring comes from inside the wall Break a hole in the mounting plate s rubber grommet and pull the cable through the grommet s hole Then run the cable through the hole near the bottom of the sensor unit so it comes out the front Using two of the included mounting screws attach the mounting plate to the wall Then reattach the sensor unit to the mounting plate connect the wires...

Page 7: ...wo stacked Power Tx Rx Tx Rx Power Alarmsignal Tx Ch1 Rx Ch1 Tx Ch2 Rx Ch2 N C Alarm ch 1 N C Alarm ch 2 Example connection 2 In line Single Channel Control panel 12 24VAC VDC Power Tx Rx N C Alarm signal Tx Power Rx Tx Rx N C Alarm signal Control panel 12 24VAC VDC Control panel 12 24VAC VDC Control panel 12 24VAC VDC SECO LARM U S A ENFORCER Quad Photobeam Detectors ...

Page 8: ...e beam channel switch of the transmitter side and receiver side See pg 3 fig 1 for switch location and table 2 for switch position Freq channel CH1 CH2 CH3 Switch position CH4 1 2 1 2 Table 2 Channel Beam Frequency Selection Chart 1 2 1 2 NO NO NO NO Fig 9 Receiver Detail Fig 10 Included BeamAlignment Template Use the included SECO LARM template to aid in aligning the transmitter and receiver SECO...

Page 9: ...uzzer Off 9 Turn On the beam strength Indicator DIP switch fig 9 If the beams are not aligned the indicator will display little or no beam strength see fig 12 10 Cover the top sensor on the receiver Adjust the horizontal angle of the receiver s lower sensor vertically and horizontally until the beam strength indicator displays a strong signal Repeat while covering the lower sensor and adjusting th...

Page 10: ... adjustment knob sets how long the beam can be interrupted before triggering the alarm see fig 14 a A short response time high sensitivity is suitable for catching fast moving intruders but more susceptible to false alarms b A long response time low sensitivity reduces false alarms but fast moving intruders may not trigger the sensor 2 Adjust the knob to the site s situation You may need to make a...

Page 11: ...__________________ Upper View 43ST Pole Size Side View Rear View Front View 15 1 4 367mm 47 16 113mm Fig 15 Dimensions 411 32 110mm Troubleshooting Transmitter LED not lit Receiver LED does not light when interrupted Beams are interrupted and LED lights but the alarm does not trigger Signal LED continuously lit Alarm trigger becomes erratic in bad weather Frequent false alarm triggers Make sure th...

Page 12: ... LARM product is warranted against defects in material and workmanship while used in normal service for three 3 years from the date of sale to the original customer SECOLARM s obligation is limited to the repair or replacement of any defective part if the unit is returned transportation prepaid to SECOLARM This Warranty is void if damage is caused by or attributed to acts of God physical or electr...