Troubleshooting:
Transmitter LED not lit
Receiver LED does not light when interrupted
Beams are interrupted and LED lights, but the
alarm does not trigger.
Signal LED continuously lit
Alarm trigger becomes erratic in bad weather
Frequent false alarm triggers
Make sure the input power to the transmitter is
12 to 24 VAC/VDC.
Check the input power to the receiver is 12 to 24
VAC/VDC.
Check the continuity of the wiring from the
receiver to the alarm.
Clear any obstacles between the transmitter and
receiver.
Clean the lenses of both units.
Check overall system installation.
Realign the lenses.
Adjust the response time.
Change location of transmitter and receiver.