V3.5 14/08/19
UD0089
Page 648
This Document is uncontrolled unless over stamped "CONTROLLED DOCUMENT"
3.20.5
ALARM & EVENT TYPES
Alarm Types
1.
Triple Primary PIN: Occurs when a user enters their PIN incorrectly three times or when an unrecognised
card is swiped three times.
2.
Door Left Open: Occurs when a user accesses the system and does no close the door when finished.
3.
Power Fail: Occurs when the Traka System’s mains power fails and Traka runs on its battery backup.
4.
Unauthorised Item Taken: Occurs when an item is removed from the system by an unauthorised user. This
generally can only occur in a non-locking system.
5.
Reserved Item Taken: This alarm type is not currently used.
6.
Item Undetectable: Occurs when an Item is removed from the system when the door appears to be closed.
This type of alarm can occur when a Traka System is having difficulty reading an Item, in which case the Item
is booked out and back in very quickly.
7.
No Transaction Took Place: Occurs when a user accesses the system but does not take or return any
iFobs.
8.
Overdue : Occurs when an Item goes out under a curfew and is not returned within the time limit set.
9.
iFob Emergency Release: Occurs whenever an iFob is released using the Emergency Release utility from
the iFob Menu of the System Viewer.
10.
System Has Been Reset: Occurs whenever a hardware or software reset is performed.
11.
User’s Quota Exceeded: Occurs when a user takes more Item than their quota allows.
12.
Door Opened Manually: Occurs when the door is opened without a user swiping their card or entering their
PIN. This would typically occur if the Master Key is used to open the door or if the door has not been closed
properly or the door has been forced open.
13.
Alarm Table is Full: Occurs when the alarm memory within the Traka System has become full. When the
alarm memory becomes full, it will start to overwrite the oldest alarms in order to keep the most recent
information.
14.
Transaction Table is Full: Occurs when the transaction memory within the Traka System has become full.
When the transaction memory becomes full, it will start to overwrite the oldest transactions in order to keep
the most recent information.
15.
Data iFob CRC Failure: Occurs when the Traka System detects corrupt data when reading data from a
Data32 or Data512 iFob used with the Traka Immobilisor.
16.
Immobilisor CRC Failure: Occurs when the Traka Immobilisor System detects corrupt data when reading or
writing data from or to a Data32 or Data512 iFob.
17.
Item Returned to Wrong Location: Occurs when a user return an Item to the incorrect location.
18.
Unrecognised Item Returned: Occurs when a user returns an Item that has not been configured for that
system.
19.
Triple Secondary PIN: Occurs when a user enters their secondary PIN incorrectly three times.
20.
Data iFob Read Error: Occurs when the Traka System was unable to read data from a Data32 or Data512
iFob.
21.
Data iFob Write Error: Occurs when the Traka System was unable to write data to a Data32 or Data512
iFob.
22.
Date & Time Before Set: Occurs before the data and time of the system is changed to record the previous
date & time. This alarm type on not currently implemented.