OPERATING INSTRUCTIONS
AGT 1060
Rev.09/2020
215
8.12.8
DIFFERENTIAL LOCK MALFUNCTION
Malfunction
Cause
Solution
The differential lock does not
engage.
The fuse is faulty.
Replace the fuse. Refer to the chapter
“Fuses”.
The
solenoid
valve
for
differential lock engagement and
disengagement is faulty.
Check the valve and replace it if
necessary. This operation can only be
performed by an authorized service centre.
(*)
The differential lock engagement
switch is faulty.
Replace the switch. This operation can
only be performed by an authorized
service centre. (*)
8.12.9
ELECTRICAL SYSTEM MALFUNCTION
Malfunction
Cause
Solution
There is no power supply to the
electrical system.
The fuse is faulty.
Replace the fuse. Refer to the chapter
“Fuses”.
Discharged battery.
Charge or replace the battery. Refer to the
chapter “Changing the battery”.
The
battery
terminals
are
oxidised.
Clean and grease the terminals. Refer to
the chapter “Changing the battery”.
The main battery switch is
damaged or faulty.
Replace the main switch. This operation
can only be performed by an authorized
service centre. (*)
The ground wires are not in
contact with the tractor’s chassis.
Check the wire connections. Consult an
authorized service technician. (*)
The warning lamp for the battery
illuminates while the engine is
running.
The belt is loose or damaged.
Check the belt tension, if the belt is worn
out, replace it. Refer to the chapter
“Maintenance”.
Alternator failure.
Replace the alternator. This operation can
only be performed by an authorized
service centre. (*)
Dashboard malfunction, before the
engine is started.
Discharged battery.
Charge or replace the battery. Refer to the
chapter “Changing the battery”.
The warning lamp for engine oil
pressure illuminates while the
engine is running.
Low oil level.
Check the engine oil level and add if
necessary.
Refer
to
the
chapter
“Maintenance”.
The engine oil filter is blocked.
Replace the oil filter. Refer to the chapter
“Maintenance”.
Engine failure.
Shut
off
the
tractor’s
engine
immediately!
Contact an authorized
service centre.
The warning lamp illuminates on
the coolant temperature gauge
while the engine is running.
The radiator is dirty or blocked
(radiator fins).
Clean the radiator fins. Refer to the
chapter “Maintenance”.
The coolant level in the system is
too low.
Check the coolant level and add if
necessary. Refer to the chapter
“Maintenance”.
The cooling system pump is
faulty.
Replace the fuel pump. This operation can
only be performed by an authorized
service centre. (*)
(*) - These operations should only be performed by an authorized service technician!
Summary of Contents for AGT 106
Page 202: ...OPERATING INSTRUCTIONS AGT 1060 Rev 09 2020 201 Rear left side view of the tractor Fig 237...
Page 240: ...OPERATING INSTRUCTIONS AGT 1060 Rev 09 2020 239 Fig 252 9 11 2 WIRING DIAGRAM OF THE ENGINE...
Page 241: ...OPERATING INSTRUCTIONS AGT 1060 Rev 09 2020 240 Fig 253 9 11 3 WIRING DIAGRAM OF THE DASHBOARD...
Page 242: ...OPERATING INSTRUCTIONS AGT 1060 Rev 09 2020 241 Fig 254 9 11 4 WIRING DIAGRAM OF THE CAB...
Page 244: ...OPERATING INSTRUCTIONS AGT 1060 Rev 09 2020 243 NOTES...